Product overview and engineering role
The dual-axis inclinometer watches pitch and roll on structures, slopes, bridges, tunnels, and large machines. A low-noise accelerometer and temperature compensation keep the zero stable for a long time across wide temperature and vibration. The output can feed SCADA, a geohazard platform, or a building structural-health system.
SimtoLink supplies a mounting-base note, an initial zero procedure, and a threshold-policy template. Uplink is LoRa or RS485, by order code. Volume jobs can change the ingress rating and cable length, and can add help with a third-party metrology submission.
Reliability and site fit
The unit has passed the relevant CE and FCC tests. Ports include surge and reverse-polarity protection. Reinforced grounding and a zoned layout cut ground-loop and common-mode noise. Outdoor and coastal sites can specify a higher ingress rating and a corrosion-resistant coating.
Software accepts a batch parameter import, threshold rules, and event or waveform capture where the model includes them. Configuration and firmware can move over the air. Close acceptance on site in three steps: power-on self-test, time sync, and a sample check. Metering or safety use can add a third-party metrology submission and type-test documents.
Key hardware parameters
Use this table for the typical order when you write a selection note or a bid clause. A wider span, redundant supply, or an intrinsically safe build is quoted separately, with the hardware specification and the commissioning guide. Sibling order codes can shift slightly; follow the nameplate and the papers packed with the sensor.
| Parameter | Specification | Notes |
|---|---|---|
| Axes | Dual axis (pitch / roll) | See the specification |
| Range | ±30° typical, extendable | Optional at order |
| Resolution | ≤0.001° class, typical | Depends on range |
| Update rate | 8 Hz | Configurable |
| Communications | LoRa / RS485 | Optional at order |
| Power | DC 12~48 V | Wide input |
| Ingress | IP65 | Outdoor cabinet or structural face |
| Operating temperature | -28~70 ℃ | Industrial |
| Mounting | Screwed or bonded base | Surfaces must be coplanar |
| Calibration | Zero and gravity | Can return to the factory |
Typical applications
Three ways this sensor is usually installed, useful when you are still selecting and when you prove the link to the platform:
Slopes and geohazards
On landslide masses, retaining walls, and tunnel portals, with rainfall and displacement for a joint warning. Low-power backhaul and threshold-triggered waveform capture.
Bridges, tunnels, and structural health
Watches the attitude of piers, beams, and bearings. Data goes to the SHM platform for the annual inspection and a load-test comparison.
Construction machinery and gantry cranes
On the boom, the slewing platform, or the rail foundation, for anti-tip monitoring, an attitude interlock, and remote inspection.
Installation, grounding, and maintenance
- Confirm the supply range and polarity before the breaker is closed. Meter the bus if the drawing is unclear.
- Run communications on shielded twisted pair, bond the shield at one end only, and keep it off long parallel runs with power cable.
- Prove two-way access and a threshold trip in the lab before the sensor leaves for site.
- Outdoors, give water a way out and air a way through, inspect the seal faces, and hold the lightning earth to the local limit.
- In continuous service, sample-check the sensor and archive logs every 24 months.
Ordering, documentation, and support
The pack includes the hardware specification, an outline drawing, a wiring table, and a sample project. A volume order can add a sample review and a resident factory inspection. Warranty and calibration stay with the contract and the documents that travel with the sensor.
Further reading
Related hardware for attitude and geohazard monitoring: