Tool Cabinet RFID Tag

Asset tags · Industrial hardware ratings · SimtoLink

Low driftComponent grade
AC 220VTypical supply
RS485Uplink
IP67Enclosure protection

Product overview and engineering role

The SimtoLink tool-cabinet RFID tag closes the loop on whether a tool is in its place, or out on loan, for machining, maintenance, and power operations. It can be stuck on or set into a compartment, a gauge box, or an insulating-rod rack, and works with a cabinet reader or a handheld gun for an inventory within seconds, a reminder when a loan is overdue, and a named owner. Selection turns on read range next to metal, how the tag wears in oil, and a one-to-one map from UID to asset code.

Against an EAM, an MES, or a work-order system, define the states checked out, in the cabinet, sent for test, and scrapped. SimtoLink can supply a write-code rule, a cabinet antenna layout, and a data template for issuing tags in volume.

Reliability and field fit

On electrical safety and EMC, the tag has passed the related CCC test items. Ports include surge and reverse-polarity protection. Reinforced grounding and a partitioned layout cut ground-loop and common-mode risk. Outdoor or coastal sites can take a higher ingress rating and a corrosion-resistant coating.

Settings can be imported in bulk, thresholds can be written, and models that include the feature can keep event video or a waveform. Configuration and firmware go out over the air. On site, close acceptance in three steps: a power-on self-test, time sync, and a sample check. Where the tag is used for metering or safety, SimtoLink helps send it to a third-party metrology institute and provides the type-test papers.

Key hardware parameters

The table is a typical build of this tag, for selection and for a technical clause in a tender. A wider range, redundant power, or an intrinsically safe version is quoted separately; ask SimtoLink for the hardware specification and the installation and commissioning guide. Order codes in the family can differ slightly. The nameplate and the papers shipped with the tag govern.

Parameter Specification Notes
Band 860~960 MHz Region code
Read range 0~3 m Depends on the antenna
Memory Sensor data area Write lock
Ingress IP67 On-metal construction
Battery Single-use lithium thionyl chloride Life 3~5 years
Sensing None Sample period can be set
Communications EPC Gen2 Encryption
Mounting Cable tie Metal surface
Operating temperature -26~67 ℃ Cold chain optional
Standard EPCglobal Interoperability

Typical applications

Four forms this tag usually takes, for design and for judging the return:

Machining and assembly lineside

Loan records for cutters, fixtures, and gauges, so the wrong tool is taken less often and fewer tools go missing.

Power and rail maintenance

Safety tools stay in a fixed place, and the test interval and certificate status raise a linked alarm.

Aviation MRO

Special toolboxes and spares cabinets are checked in place, for airworthiness and for an audit sample.

Construction general contractor

The site tool room is counted with the cabinet closed at night. A tool that leaves when it should not is flagged, and the subcontractor is named.

Installation, grounding, and maintenance

  • Confirm supply range and polarity before power is applied. When needed, measure bus voltage and breaker rating with a multimeter.
  • Use shielded twisted pair for the communications cable, ground the shield at one end, and do not run it for a long distance in the same bundle as high-power cable.
  • On the first connection, prove bidirectional read and write and a threshold trip against the platform in the lab, then take the tag to site.
  • Outdoors, put drainage and ventilation first. Inspect the seal face on rounds. Lightning-protection earth resistance has to meet the local code.
  • While the tag stays in service, take a sample check and archive the logs every 6 months.

Ordering, documentation, and support

SimtoLink can supply the hardware specification, outline drawings, a wiring table, and an example project for this tag. Volume orders can include a sample review and inspection at the factory. Warranty and calibration follow the contract and the papers shipped with the tag.

Further reading

Need selection and delivery support for the tool-cabinet RFID tag?

Contact SimtoLink for the specification, a sample unit, and volume pricing

Contact SimtoLink