Fluorescence Dissolved-Oxygen Probe

Process Sensing · Industrial hardware · SimtoLink

Low driftComponent grade
DC 12~48VTypical supply
RS485Uplink
IP67Enclosure protection

Product overview and engineering role

Built for process-sensing deployments. The figures on this page support selection, bid clauses, and later spot checks. Measurement and communications run on a dual-core lockstep MCU so behavior stays predictable across wide temperature, wide voltage, and EMI. Terminals unplug, key chips carry a watchdog and a redundancy check, and critical firmware can be signature-checked and rolled back for volume shipments and remote service.

By default the probe offers CAN-FD and a standard industrial connector, so it can sit on an existing SCADA, energy, or IoT platform. SimtoLink supplies a southbound point-list template and northbound MQTT and HTTP examples. Volume jobs can add silk-screen, harness length, protocol mapping, and a calibration certificate.

Reliability and site fit

CCC test items cover electrical safety and EMC. Ports include surge and reverse-polarity protection. Reinforced grounding and a zoned layout cut ground-loop and common-mode risk. Outdoor and coastal sites can specify a higher ingress rating and a corrosion-resistant coating.

Software accepts a batch parameter import, threshold rules, and event or waveform capture where the model includes them. Configuration and firmware can move over the air. Accept on site in three steps: power-on self-test, time sync, and a sample check. Metering or safety use can add a third-party metrology submission and type-test documents.

Key hardware parameters

Treat the table as the typical build when you write a technical schedule. A wider span, redundant power, or an intrinsically safe variant is quoted with the hardware specification and the commissioning guide. Order codes in the family can differ; the nameplate and the papers in the box govern.

Parameter Specification Notes
Measurement Water quality Factory calibration certificate
Range ±50 g Extendable
Accuracy / linearity ±0.27 %FS Compensated over the full temperature span
Frequency response 0~100 Hz IEPE optional
Medium temperature -24~93 ℃ Depends on the probe
Power Loop-powered Surge protection
Output 4~20mA Isolated
Process connection Immersion 316L stainless steel
Ingress protection IP67 Rated for long immersion
EMC GB/T 17626 Level 4 Industrial sites

Typical applications

Four deployments, useful when you design the scheme and estimate payback:

Biological treatment at a wastewater plant

Closed-loop dissolved oxygen in aeration tanks, oxidation ditches, and MBR basins, so aeration energy drops and filamentous bulking is less likely.

Aquaculture and recirculating systems

Online dissolved oxygen in grow-out ponds, hatcheries, and biofilters, tied to aerators and feeding so surface-gasping losses fall.

Rivers and reservoirs

Dissolved-oxygen trends from cross-sections and buoy stations, for black-and-odorous water assessments and ecological-flow dispatch.

Fermentation and biopharma

The probe watches the oxygen gradient in a fermenter and works with agitation and air rate to raise yield.

Installation, grounding, and maintenance

  • Confirm the supply range and polarity before power-up. If the circuit is unfamiliar, check bus voltage and breaker rating with a meter.
  • Run the signal on shielded twisted pair, bond the shield at one end, and keep it off long parallel runs with power cable.
  • Prove two-way reads and writes and a threshold trip against the platform in the lab before the probe goes to site.
  • Outdoors, give water a way out and air a way through, inspect the seal faces, and hold the lightning earth to the local limit.
  • In continuous service, pull a sample check and archive logs every 24 months.

Ordering, documentation, and support

SimtoLink supplies the hardware specification, an outline drawing, a wiring table, and a sample project. Volume orders can include a sample review and a factory inspection. Warranty and calibration follow the contract and the papers shipped with the probe.

Further reading


Need help selecting and delivering a fluorescence dissolved-oxygen probe?

Contact SimtoLink for the specification, a sample, and volume pricing.

Contact SimtoLink