PV Combiner-Box Communication RTU

Remote terminal · Industrial-grade hardware · SimtoLink

Isolated designComponent class
AC 220VTypical supply
EthernetUplink
IndoorEnclosure

String data out of the combiner box

The RTU gathers string current, string voltage, and the surge-arrester state. It polls inverters and meters over RS485, then sends the plant control room a report over 4G or another link. A wide-range 110VDC/220VDC or AC supply matches the bus already in the combiner box.

High-temperature derating fits a cabin on a color-steel roof. SimtoLink supplies a string address table, a protocol map, and a batch commissioning script, so a failed string can be found without walking the array.

What the box has to survive

The ports are tested to the relevant items of IEC 61000-4 level 4, with surge and reverse-polarity protection. Ground is zoned so a loop or a common-mode hit is less likely to drop a string reading. Outdoor and coastal orders can take a higher ingress rating and a corrosion coating.

Parameters and thresholds load as a batch. Selected models store an event or a waveform. OTA carries settings and firmware. Accept the RTU with a power-on self-test, a time sync, and a sample of points. For metering or safety, SimtoLink helps with a third-party metrology submission and the type-test file.

Hardware figures

Typical order, for selection and for a bid schedule. For a wider range, a redundant supply, or an intrinsically safe explosion-proof variant, ask SimtoLink for the hardware specification and the installation guide. Order codes can differ slightly; the nameplate and the papers in the box decide.

Item Specification Note
Telemetry / status 64/128 Configurable point table
Control / setpoint 16/8 Checkback
Uplink BeiDou short message Active/standby switchover
Downlink Several RS485 channels Isolated
Supply DC 24V solar Holds through a power loss
Clock Timekeeping <2s/day SOE 1 ms
Ingress IP65 outdoor enclosure Lightning protection class III
Safety GB/T 13729 Type test
MTBF >80,000 hours Room temperature
Installation Wall mount Anti-theft lock

Where the RTU sits on a PV plant

Four plant types, so the uplink and the string map can be judged before the order.

Commercial rooftops

Several combiner boxes report to one cloud, and cleaning or an I-V diagnosis can be issued as a work order.

Ground-mounted plants

Array blocks are gathered where fiber has not been pulled, so those blocks are no longer a blind spot.

PV, storage, and charging on one site

PCS and BMS share the link and the timestamp, which is what an energy-management policy needs.

Village and livelihood PV

On a weak network the report resumes after a break, which settlement and the maintenance score both rely on.

Install, ground, and revisit

  • Check the supply window and polarity before the RTU is powered. Measure the bus and the breaker if the combiner feed is uncertain.
  • Shielded twisted pair, shield landed once, kept off long runs of power cable.
  • Prove read, write, and one threshold against the host in the workshop, then take the RTU to the roof.
  • Outdoors, let water leave and air move, inspect the gasket, and keep the lightning earth inside the local rule.
  • Every 6 months, sample a set of strings and file the log.

Order, documents, and support

SimtoLink supplies the hardware specification, the outline drawing, a wiring table, and a sample project. Volume orders can include a sample review and a factory inspection. Warranty and calibration follow the contract and the papers in the box.